FDGW55 Guided Wave Radar Level Instrument

Features: Stainless steel 316L/ ceramic antenna which can stand higher temperature and pressure.
Application: Liquid measurement, high temperature, high pressure, complex process and conditions.
Max Measurement Range: Cable: 30m/Bar: 6m
Measurement Accuracy: ±10mm
Process Connection: G1½A/G2A/1½NPT
Detector Material: Stainless steel 316L/ ceramics
Diameter of Steel Cable: Φ4mm, Φ6mm/Φ10mm
Process Temperature: -200…400°C
Process Pressure: Vacuum…400bar
Signal Output: Two-wire 4…20mA/HART

Detailed Description:
FDGW55

Approval
P Standard (Non-explosion-proof)
I Intrinsically Safe (Exia IIC T6)
C Intrinsically Safe+Ship Approval (Exia IIC T6)
G Intrinsically Safe+Flameproof (Exd [ia]ia IIC T6)

Detector Type/Material
A Cable Type/Stainless Steel 316L/PTFE
B Bar Type/Stainless Steel 316L/PTFE

Process Connection
GP Thread G1½A
KP Thread G2A
NP Thread 1½NPT
YP Special Design

Electronic Components
B (4~20)mA/HART 2-wire
C (4~20)mA/(22.8~26.4)V DC /HAR 2-wire/4-wire
D (198~242)V AC/HART 4-wire

Housing/Protection Level (Note)
A Aluminium/IP67
B Plastic/IP66
D Aluminum (Two-chamber) /IP67
G Stainless Steel 316L/IP67

Process Temperature/pressure
A  (-200~400)℃/(vacuum~4)MPa
B  (-200~400)℃/(vacuum~40)MPa

Cable Entry
M  M20x1.5
N  ½NPT

Display/Programming
A  Yes
X  No

Cable(bar) length
5-digit(Unit: mm)

Note: Intrinsically Safe (Exia IIC T6) must use “B” electronic component and “A” housing; Intrinsically Safe+Ship Approval (Exia IIC T6) must use “B” electronic component and “G” housing; Intrinsically Safe+Flameproof (Exd [ia]ia IIC T6) must use “C”“D” electronic components and “D” housing; standard flange size refers to GB/T9119-2000 PN1.6MPa size with thickness of 15.

Hot:1269 【Print this page】【Return back